KB AM03 2AI 1AO Analog I/O Signal Board
$23.00
KB AM03 is a signal board with 2 analog inputs and 1 analog output. It supports voltage or current input signals, voltage and current output signals, and uses SB CM01 configuration.
Description
KB AM03 PLC signal board with two voltage or current inputs, one voltage and current output, and SB CM01 configuration.
The KB AM03 analog I/O signal board helps a PLC system handle both incoming and outgoing analog signals in one board. It provides two analog input channels that support voltage or current signals, plus one analog output channel supporting voltage and current signals. Configure the board as SB CM01 to access the specified input and output word registers.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | KB AM03 |
| Product Type | Analog I/O signal board |
| Analog Inputs | 2 |
| Analog Input Signal Type | Voltage or current |
| Analog Outputs | 1 |
| Analog Output Signal Type | Voltage and current |
| Configuration Selection | SB CM01 |
| Input Register Mapping | IW600, IW602 |
| Output Register Mapping | QW600 |
What Does This Signal Board Do?
The KB AM03 signal board adds two analog input channels and one analog output channel to a compatible PLC configuration. It allows the PLC to read connected voltage or current signals through IW600 and IW602, while providing an analog output value through QW600.
Key Features
- 2 analog inputs — receives two voltage or current input signals.
- 1 analog output — provides one output channel supporting voltage and current signals.
- Combined analog I/O — handles analog input and output functions on one signal board.
- SB CM01 configuration — configure the board as SB CM01.
- Input register mapping — analog input values are mapped to IW600 and IW602.
- Output register mapping — the analog output channel is mapped to QW600.
Compatible With
- SB CM01 configuration selection
- Voltage analog signal sources
- Current analog signal sources
- Voltage analog output circuits
- Current analog output circuits
Easy to Set Up
Configure the KB AM03 signal board as SB CM01 in the PLC configuration. Connect the required analog input and output wiring, then access the two input channels through IW600 and IW602. Use QW600 for the analog output channel.
Order With Confidence
Check the required analog input signal type, analog output requirement, and register mapping before ordering. Confirm that your PLC configuration uses SB CM01. Contact us before ordering if you have compatibility questions.
Additional information
| Weight | 0.3 kg |
|---|




Reviews
There are no reviews yet.