S7-200 Series Standard PLC

Siemens S7-200 compatible PLC for machine control and retrofit projects. Multiple CPU options (Relay/Transistor, 220VAC/24VDC) and expansion support for digital, analog and temperature modules.

RS485 (PPI / Modbus RTU) Optional Ethernet (-ETH) Up to 7 Expansion Modules Analog I/O Options
Quick Select
Need Ethernet?
Choose CPU226-*-ETH for fast download/monitoring and Modbus TCP ready networking.
Need Analog I/O?
Choose CPU228 (4AI/2AO) or add analog expansion modules (AI/AO).
Relay or Transistor?
-R for general loads; -T for high-speed switching.

Key Advantages

Siemens S7-200 Compatible
Ideal replacement for legacy S7-200 systems and machine retrofit projects.
Ethernet Option (-ETH)
Built-in Ethernet models for faster programming/monitoring and networking integration.
Flexible Expansion
Supports up to 7 modules: DI/DO, AI/AO, temperature (RTD/TC), mixed I/O.
Industrial Reliability
Stable design for panel mounting, long-term operation in industrial environments.

Model Selection (S7-200 Series Standard PLC)

Models listed vertically for better layout on all screens. Click model name to view product details.

Model DI DO AI AO RS485 Ethernet Power
CPU222-R / CPU222-T 8 6 relays / transistors None None 1 None Relay: 220VAC
Transistor: 24VDC
CPU222-R-ETH / CPU222-T-ETH 8 6 relays / transistors None None 1 1 port (10/100M adaptive) Relay: 220VAC
Transistor: 24VDC
CPU224-R / CPU224-T 14 10 relays / transistors None None 2 None Relay: 220VAC
Transistor: 24VDC
CPU224XP-R / CPU224XP-T 14 10 relays / transistors 2 1 2 None Relay: 220VAC
Transistor: 24VDC
CPU224XP-RT
Mixed output
14 4 transistors + 6 relays 2 1 2 None Relay: 220VAC
Transistor: 24VDC
CPU224XP-R-ETH / CPU224XP-T-ETH 14 10 relays / transistors 2 1 2 1 port (10/100M adaptive) Relay: 220VAC
Transistor: 24VDC
CPU225-R / CPU225-T 14 10 relays / transistors 4 2 2 None Relay: 220VAC
Transistor: 24VDC
CPU226-R / CPU226-T 24 16 relays / transistors None None 2 None Relay: 220VAC
Transistor: 24VDC
CPU226-R-ETH / CPU226-T-ETH 24 16 relays / transistors None None 2 1 port Relay: 220VAC
Transistor: 24VDC
CPU228-R / CPU228-T 16 14 relays / transistors 4 2 3 None Relay: 220VAC
Transistor: 24VDC
Legend: DI = Digital Inputs, DO = Digital Outputs, AI = Analog Inputs, AO = Analog Outputs. “-R” = Relay output, “-T” = Transistor output, “-ETH” = Built-in Ethernet.

Communication & I/O

RS485 Protocols
  • PPI communication for S7-200 compatible networking
  • Modbus RTU for HMI/SCADA/drive integration
  • Free-port protocol for custom serial devices
Ethernet (-ETH Models)
  • Fast program download/upload & online monitoring
  • Easy integration with Ethernet-based HMI/SCADA systems
  • Suitable for networking upgrades and remote diagnostics
Analog I/O (Where Applicable)
CPU228 provides 4AI / 2AO on-board analog. For additional channels, use compatible analog expansion modules (AI/AO). (If you want, I can add a dedicated block that lists your analog/temperature module SKUs with product links.)

Expansion Modules (Up to 7)

Expand digital I/O, analog signals and temperature measurement. Ideal for machine upgrades, retrofit, and control cabinet standardization.

Digital I/O
DI: 8 / 16 / 32
DO: Relay or Transistor 8 / 16 / 32
Mixed: I4Q4, I8Q8, I16Q16
Analog I/O
AI: 4 / 8
AO: 2 / 4
Mixed: AI4 + AQ1
Temperature
RTD: PT100 (4CH / 8CH)
Thermocouple: K-type (4CH / 8CH)
Distributor/OEM Note: We can help you build a standard BOM (CPU + modules + wiring) for faster stocking and delivery.

Typical Applications

Machine Retrofit
Replace legacy S7-200 PLC while keeping control logic and wiring changes minimal.
Packaging & Conveying
Counting, interlocking, speed control, and small line automation.
Temperature Control
RTD/TC expansion for heaters, ovens, drying systems and process control.
HMI/SCADA Integration
RS485 Modbus RTU or Ethernet (-ETH) for data monitoring and remote maintenance.

FAQ

Is it compatible with Siemens S7-200 programming?
Yes. It is designed for S7-200 compatible logic and common retrofit requirements. Share your existing CPU model and I/O list for a recommended replacement plan.
What is the difference between Relay (-R) and Transistor (-T)?
Relay outputs are universal for many loads; transistor outputs are preferred for high-speed switching and long cycle applications.
How many expansion modules can I connect?
Up to 7 right-side expansion modules are supported (digital, analog, temperature, mixed I/O).
Can I use Ethernet for HMI/SCADA?
Yes. Choose -ETH models such as CPU226-*-ETH for Ethernet-based integration and faster engineering workflows.

Datasheet & Manuals

Download user manual, wiring reference and communication examples. If you need a specific document version, contact our engineers.
Go to Download Center

Need Selection Help or a Quote?

Send us: your current S7-200 CPU model, DI/DO/AI/AO count, power supply requirement (220VAC or 24VDC), and whether you need Ethernet (-ETH). We will reply with 1–2 recommended solutions and a wiring suggestion.